T03.35 德国PTL灼热丝试验仪 产地:德国 PTL 产品型号: T03.35 1.概述 电器部件或零件在故障或过载条件下,可能达到过高的温度或点燃他们附近的零件,灼热丝试验仿真组件或过载的电阻之类的热源或点火源在短时间所造成的热应力,用模拟技术评定着火危险性。
详情介绍:

T03.35 德国PTL灼热丝试验仪
产地:德国 PTL
产品型号: T03.35

德国PTL灼热丝测试仪,符合标准IEC60695-2-10:2000IEC60695-2-132000(灼热丝/专线基本试验方法,灼热丝试验装置和通过试验程序)、IEC829, DIN695VDE0471.

它是将规定材质和形状的电热丝用大电流加热至试验温度(550℃-960℃)1min 后,以规定压力(1.0N)垂直灼烫试品30s,视试品和铺垫物是否起燃或持燃时间来测定电工电子设备成品的着火危险;测定固体绝缘材料及其它固体可燃材料的起燃性,起燃温度(GWIT)、可燃性和可燃性指数(GWFI

PTL Glow Wire Test Apparatus

 

The test procedure is used to examine the fire resisting properties of products if, during the application or in the case  of  a  fault,  heated  or  glowing  parts  could  be considered  as  a  short-time  ignition  source.  Loose connections  or  bad  contacts  cause  

punctually  high temperatures  on  electrical  articles,  their  components and their parts. Attention should also be paid to the fire risk  in  connection  with  textile  seat  coverings,  table-cloths, or curtains, e.g. after coming into contact with a lighted  cigarette.  

For  this  reason,  prototypes  of  all articles which could be a source of danger if they con-tact with ignition sources should be subjected to the Glow-wire Test.

 

Test Apparatus 

 

The ignition source is imitated by an electrically heated wire loop against which the sample is pressed with a 

constant force. A miniature jacket thermocouple serves

as a sensor for the loop temperature.

The sample has to be fastened to a carriage on which, by means of a tensioning cord, a weight with a force of 1 N is effective in the direction of the wire loop. Scales enable the reading of the flame height and the depth of penetration. Approx. 200 mm below the wire loop a board of pine wood, covered with a layer of tissue paper, is mounted. This device enables to judge the danger of a fire spreading through burning drops or glowing parts falling from the sample. 

 

Test Method 

 

The specimen and, if necessary, a base shall be attached relative to the wire loop in such a way to represent the most unfavourable practical case. The scales of the measuring device shall be adjusted and the penetration depth of the loop shall be limited by the adjustable stop. After returning and covering the specimen the loop shall be heated up to the specified temperature. 

When the loop has maintained the testing temperature for at least 60 seconds, the specimen can be briskly led up to the loop. From the moment of contact, an operation time of exactly 30 seconds must be kept. Then the penetration depth is read and the specimen is slowly returned to its starting position. During and after the operation the burning behaviour of the specimen and the tissue paper on the wooden board has to be observed.

 

S t a n d a r d  o u t f i t : 

 

1 wire loop of nickel-chromium, with clamping mechanism,

1 carriage with Cardanic holding device for the specimen, five-fold adjustable,

1 rail system with ground running surfaces,

1 fine rope pull mechanism with weights for loads of 1 ?0,2 N,

1 indicating device for the depth of penetration, with maximum pointer and stop,

1 scale to measure the flame height, multiple adjustable,

1 high  current  isolating  transformer  to  heat  the  wire  loop,  with  series  connected

variable ratio transformer, to set the temperature up to 960℃

1   miniature  jacket  thermocouple  Chromel-Alumel,  with  plug  almost  free  from  thermoelectric voltage and with compensating lead, 

1   temperature indicating instrument to indicate the temperature of the glow-wire loop,  with digital display, measuring range 0...1000℃, class 0,5, built-in operable, see  Fig. 1 and 3, can be recalibrated, with compensation of the ambient temperature.  1 housing, desk shaped, with all necessary 

electrical components, with safety switch and 2 keys.

 

D e s i g n : testing device as Fig. 2, moun-ted on housing of sheet steel, papyrus-white structure varnished, plan dimensions approx. 400 mm x  400 mm, total height approx.  570 mm, carriage and specimen holding device of corrosion-protected material, including  2 cm2 foil of fine silver 99,8  %,  0,06 mm thick, for 

calibration   of   the   temperature   indicating instrument, board of pine wood, 10 mm thick, wrapping  tissue  and  mains  connection  cord set, for connection to A.C. 230 V, 50 to 60 Hz,other voltages or frequencies: on request

 

S p a r e  p a r t s :

The articles T 03.81 to T 03.93 are wearing parts and have no guarantee

                                Article-No.

T03.81 Glow-wire loop 0,5

T03.82 Glow -wire  loop  1 , 0

T03.84 Miniature -jacket - thermocouple  1 , 0

T03.86 Miniature -jacket - thermocouple  0 , 5

T03.89 Silver foil , 2 cm 

      Wrapping  Tissue 

      Fine  Wire  Brush 

      Board  of  Pine  Wood 
 
如需要详细资料,请来电咨询13631576199吴先生
 